 EM 4000 is a 4000 W FM transmitter made up of the EM 100DIG exciter and a
 control unit which combines the power of two AM 2000 FM amplifiers.
 
 The 100W FM exciter/modulator, EM 100 DIG, is controlled by 
microprocessor, that allow a lot of applications like power level 
control at night to save energy, and the whole monitoring and adjusting 
of several parameters of the equipment, like input level and deviation.
 
 Each AM 2000 includes eight 300W high-efficiency MOSFET technology 
amplifying modules, fed by 2 independent switching power supplies, which
 are made to withstand the working conditions. The amplifiying modules 
works independently thanks to a power combining structure that provides 
high isolation between them.
 
 The equipment includes a low-pass filter at the antenna output, EMI 
filters at the utility connection and an internal transient suppressor. 
The LCD display shows the amplifier main parameters: supply voltages, 8 
module currents, direct, reflected and input power, power loss in the 
internal unbalance load and three temperature sensors. The amplifier 
control system stores in their memory all events and alarms detected, 
showing time and date of occurrence.
 
 Smart temperature protection: if temperature rises up to a level 
dangerous for the modules, the output power is reduced until the 
temperature goes back to a “normal” state. If, even with the power 
reduction, the temperature keeps on rising, then the amplifier is 
stopped until the temperature goes down.
 
 Reflected power protection (load mismatch): when the control system 
detects that the V.S.W.R. is dangerous for the modules, it reduces 
automatically their output power so as not to exceed the internal 
security level. Besides, there is a fast protection system that 
instantaneously turns off the modules polarization when it detects a 
peak on the reflected power sensor. 
 
 Automatic gain control: it reduces the gain in the case of excessive 
driving power, keeping the adjusted output power despite temperature 
changes. The control allows manual power adjustment by means of the 
front keyboard.
 
 Telemetry systems: analogue telemetry (direct and reflected power 
measure), digital RS-232 telemetry and remote control, remote control 
through open-close contacts and a multi-device bus connection for 
internal use.
 TECHNICAL FEATURES OF THE em 4000
 EM 100 DIG
 AUDIO
 S/N ratio (30 ~ 20000Hz) Mono: ≥78dB (86dB typical)
 Stereo: ≥72dB (77dB typical)
 weighted S/N (CCIR)  Mono: ≥75dB (81dB typical)
 Stereo: ≥68dB (72dB typical) 
 T.H.D. Distortion 
 (limiting threshold adjusted at 150kHz deviation)
 75 KHz deviation  <0.05% (typical 0.02%) 
 150 KHz deviation <0.2% (typical 0.05%) 
 stereo channels crosstalk (L / R)  <-50dB (with external encoder)
 < -60dB with internal encoder (100 ~ 5000Hz)
 < -50dB with internal encoder (30 ~ 15000Hz)
 audio input frequency response
 30 Hz ~ 15 KHZ (pass band) ±0.1dB
 f >19 KHZ (rejected band) >50dB
 stereo input (MPX) frequency response ±0.1dB  (10Hz ~ 100KHz)
 aux input (SCA/RDS) frequency response   ±0.2 dB  (10KHz ~ 100KHz)
 input levels
 Audio and MPX (AT ±75 KHz deviation)  -3.5 ~ +12.5dBm adj.
 SCA/RDS (AT ±7.5 KHz deviation) -12 ~ +3.5dBm adj.
 SCA/RDS (AT ±2 KHz deviation)  -24 ~ -8dBm adj.
 imput impedance
 Audio and MPX  10KΩ balanced or 600Ω unbalanced (selectable)
 Auxiliar SCA/RDS  10KΩ
 Connectors
 Audio  XLR Female
 MPX, Auxiliar (SCA/RDS)  BNC Female
 common mode input rejection (20 to 15000HZ) >50dB (>60 dB typical)
 MPX OUTPUT LEVEL  0 ~ +10dBm (for 75KHz deviation)
 deviation limit 0 ~ +7dBm adj.
 Pre-EMphasis time constant  50 or 75μs ?2%
 ModulatiOn
 frequency range  87.5 ~ 108MHz
 modulation mode  FM  (75KHz peak deviation)
 MoDULATION CLASS F3E, F8E
 carrier frequency tuning steps  10 / 100KHz
 frequency offset <±200Hz
 frequency drift Thermal <250Hz from -10? to 45?C
 Stability <100Hz / year
 RF
 RF output power 0 ~ 100WRMS adj.
 MAX. reflected power allowed 10W
 harmonicS <-70dBc
 spurious  <-80dBc (-95dBc typical)
 output impedance 50Ω (N Female Connector)
 control and protection - Protection against spurious emissions
 - Reflected power protection 
 - Power level automatic reduction at night 
 general featuRes
 AC power supply  90 ~ 260VAC, 50/60Hz
 power consumption 180VA (100W RF)
 temperature range  -10 ~ 45?C
 control signals RF enable
 RF output power indication
 ON AIR
 Failure indication
 RS-232
 Dimensions  3RU (19" rack)
 438 x 132 x 334mm without handles
 weight 11Kg (24.2Lbs)
 
 AM 4000
 FREQUENCY RANGE 87.5 ~ 108MHz
 OPERATION CLASS B
 INPUT RETURN LOSS <-20dB
 INPUT POWER 30W
 OUTPUT POWER 4kW nominal, manual and automatic adjustment (5kW max.)
 typical RF efficiency 70%
 cooling Forced air
 harmonics level <83dBc
 input / output impedance 50W
 rf input connector N female
 rf output connector EIA 1-5/8’’
 rf monitor connector BNC female
 supply  -Three-phase 380Vac + Neutral; 220Vac ±10%  50/60Hz 
 - Three-phase triangle 220Vac without neutral ±10%  50/60Hz
 CONSUMption <10000W
 PROTECtions -Reflected, Forward power, overdrive, overcurrent In each 2000W module:
 -Smart Temperature protection
 -Reflected power protection (load mismatch):
 PRFL automatic control + Fast protection
 -Automatic Gain Control
 -Real-time events register
 -Exciter inhibition
 TELEMETRY AND REMOTE CONTROL -Analog telemetry (direct and reflected power measurement)
 -Telemetry and RS-232 digital remote control
 -Remote control by open / closed contacts 
 -Multi-device bus
 WORKING TEMPERATURE -5 to +40ºC
 DIMENSIONS 35RU standard 19’’ 
 WEIGHT 276Kg (607.2Lbs)
 
 general FEATURES OF THE em 6000
 DIMENSIONS 1 standard rack of 19’’ and 25
 WEIGHT ~246Kg
 maxIMUM height of Operating 4500m standard ( with overpressurization 6000m)
 consumption <10000W,
 POWER SUPPLY  380V three-phase, ±10%
 operating humidity  95%
 operating temperaturE -5ºC - +40ºC
 MAX. OUTPUT POWER 4000W